LEYBOLD
501S |
Dry Compression Vacuum Pump for SemiconductorManufacturing.
Self monitoring system, digital display. Oil-free operation.
Pumping Speed: 480 m^3/h.
200/208/240V, 3 Ph, 60 Hz, CE.
Tested and in good working condition, not rebuilt at this price..
$8,500 |
View Details and Photo
|
|
LEYBOLD
501S |
Dry Compression Vacuum Pump for Semiconductor Manufacturing.
Self monitoring system, digital display. Oil free operation.
Pumping Speed: 480 m^3/h.
200/208/240V, 3 Ph, 60 Hz.
Tested and in good working condition, not rebuilt at this price..
$8,500 |
View Details and Photo
|
|
LEYBOLD
501S |
Dry Compression Vacuum Pump for Semiconductor Manufacturing.
Self monitoring system, digital display. Oil-free operation.
Pumping Speed: 480 m^3/h.
200/208/240V, 3 Ph, 60 Hz, CE.
Tested and in good working condition, no rebuilt at this price..
$8,500 |
View Details and Photo
|
|
LEYBOLD
501S |
Dry Compression Vacuum Pump for Semiconductor Manufacturing.
Self monitoring system, digital display.
Oil-free operation.
Pumping Speed: 480 m^3/h.
200/208/240V, 3 Ph, 60 Hz, CE.
Tested and in good working condition, not rebuilt at this price..
$8,500 |
View Details and Photo
|
|
LEYBOLD
COOLPAK UCC 066S |
Cryo Compressor.
NICE CONDITION..
$1,950 |
View Details and Photo
|
|
LEYBOLD
IPC-2 |
Pressure Converter Valve.
Three position valve extends
sampling pressure range.
2-3/4 in. O.D. conflat..
$500 |
View Details and Photo
|
|
LEYBOLD
TMP 3500 |
Large Turbo.
Bad bearings in turbo.
ASA 16 flange..
$1,500 |
View Details and Photo
|
|
LEYBOLD
TURBOVAC 3500C |
Large Turbopump with Controller. Pumping Speed: 3600 l/s. ISO Flange: 15-3/4 in. ID, 17-3/4 in. OD. 220V, 1 Ph, 50/60 Hz, 14A..
$12,000 |
View Details and Photo
|
|
LEYBOLD
UL 100 PLUS |
Helium Leak Detector with Partial Flow Pump option.
Partial flow pump option and automatic valving permits quick testing of large or contaminated parts.
Lowest detectable leak rate 2 x 10^-10 mBar ltr/sec.
Turbo pumped. Automatic range switching.
120V, 60 Hz..
$12,500 |
View Details and Photo
|
|
LEYBOLD
UL 500 |
Helium Leak Detector.
Warm up time less than 5 minutes.
Quantitative leak testing from inlet pressures starting at 100 mBar (75 torr).
Fast automatic range switching.
Automatic zero correction.
Max. measurable He leak rate: 10 atm cc/sec.
Min. measurable leak rate: 2 x 10^-10 atm cc/sec..
$12,500 |
View Details and Photo
|
|
LEYBOLD
UL 500 |
Helium Leak Detector.
Warm up time less than 5 minutes.
Quantitative leak testing from inlet pressures starting at 100 mBar (75 torr).
Fast automatic range switching. Automatic zero correction.
Max. measurable He leak rate: 10 atm cc/sec.
Min. measurable leak rate: 2 x 10^-10 atm cc/sec..
$12,500 |
View Details and Photo
|
|
LEYBOLD
UL 500 |
Helium Leak Detector.
Warm up time less than 5 minutes.
Quantitative leak testing from inlet pressures starting at 100 mBar (75 torr).
Fast automatic range switching.
Automatic zero correction.
Max. measurable He leak rate: 10 atm cc/sec.
Min. measurable leak rate: 2 x 10^-10 atm cc/sec..
$12,500 |
View Details and Photo
|
|
LEYBOLD
UL 500 |
Helium Leak Detector with Optional D65B Large Volume Auxiliary Pump.
Warm up time less than 5 minutes.
Quantitative leak testing from inlet pressures starting at 100 mBar (75 torr).
Fast automatic range switching.
Automatic zero correction.
Max. measurable He leak rate: 10 atm cc/sec.
Min. measurable leak rate: 2 x 10^-10 atm cc/sec..
$12,500 |
View Details and Photo
|
|
LEYBOLD
UL 500 |
Helium Leak Detector.
Warm up time less than 5 minutes.
Quantitative leak testing from inlet pressures starting at 100 mBar (75 torr).
Fast automatic range switching.
Automatic zero correction.
Max. measurable He leak rate: 10 atm cc/sec.
Min. measurable leak rate: 2 x 10^-10 atm cc/sec..
$12,500 |
View Details and Photo
|
|
LEYBOLD
UL 500 DRY |
Helium Leak Detector with Dry Vacuum System.
Wide dynamic measurement range over 14 decades.
Auto-ranging, auto-zero and auto-cal.
Turbo molecular pump.
Smallest detectable leak rate: 5 x 10^-11 mbar x L x S-1.
Largest detectable leak rate: 10 mbar x L x S-1.
Original mfg. price when new $72,000.
208V, 3 Ph, 60 Hz, CE..
$15,000 |
View Details and Photo
|
|
LEYBOLD
UL 500 DRY |
Helium Leak Detector with Dry Vacuum System.
Wide dynamic measurement range over 14 decades.
Autoranging, autozero and autocal.
Turbo molecular pump.
Smallest detectable leak rate: 5 x 10^-11 mbar x L x S-1.
Largest detectable leak rate: 10 mbar x L x S-1.
208V, 3 Ph, 60 Hz, CE..
$15,000 |
View Details and Photo
|
|
LEYBOLD
UL 500 DRY |
Helium Leak Detector with Dry Vacuum System.
Wide dynamic measurement range over 14 decades.
Auto-ranging, auto-zero and auto-cal.
Turbo molecular pump.
Smallest detectable leak rate: 5 x 10^-11 mbar x L x S-1.
Largest detectable leak rate: 10 mbar x L x S-1.
Original mfg. price when new $72,000.
208V, 3 Ph, 60 Hz..
$15,000 |
View Details and Photo
|
|
LEYBOLD
UL 500 DRY |
Helium Leak Detector with Dry Vacuum System.
Wide dynamic measurement range over 14 decades.
Auto-ranging, auto-zero and auto-cal.
Turbo molecular pump.
Smallest detectable leak rate: 5 x 10^-11 mbar x L x S-1.
Largest detectable leak rate: 10 mbar x L x S-1.
Original mfg. price when new $72,000.
208V, 3 Ph, 60 Hz, CE..
$15,000 |
View Details and Photo
|
|
LEYBOLD
UL 500 DRY |
Helium Leak Detector with Dry Vacuum System.
Wide dynamic measurement range over 14 decades.
Auto-ranging, auto-zero and auto-cal. Turbomolecular pump.
Smallest detectable leak rate: 5 x 10^-11 mbar x L x S-1.
Largest detectable leak rate: 10 mbar x L x S-1.
208V, 3 Ph, 60 Hz, CE..
$15,000 |
View Details and Photo
|
|
LEYBOLD
UL 500 DRY |
Dry Oil Free Helium Leak Detector.
Turbo pumped with dry roughing pump. Microprocessor controlled.
5 minute start up. Auto-tuned, auto-ranged and auto-calibrated.
Minimum detectable leak of < 5 x 10^-11 atm cc/sec.
Original mfg. price when new $72,000.
220V, 1 Ph, 60 Hz, CE..
$15,000 |
View Details and Photo
|
|
LEYBOLD
UL 500 DRY |
Helium Leak Detector with Dry Vacuum System.
Wide dynamic measurement range over 14 decades.
Autoranging, autozero and autocal.
Turbo molecular pump.
Smallest detectable leak rate: 5 x 10^-11 mbar x L x S-1.
Largest detectable leak rate: 10 mbar x L x S-1.
208V, 3 Ph, 60 Hz..
$15,000 |
View Details and Photo
|
|
LEYBOLD
VALVE |
Manual Valve.
3-3/4 in. OD ISO flange..
$150 |
View Details and Photo
|
|
LEYBOLD
WA 250 |
Single Stage Roots Pump.
Displacement: 164 cfm.
Flange: 6-5/16 in. O.D., I.D. 2-3/4 in.
4 bolt holes on 3-5/8 in. center square pattern.
Backing Pump Requirements: 49 cfm.
3450 RPM (60 Hz).
Motor: 1.5 HP. 220V/380V,
2.0A/1.2A, 50/60Hz, 3 Ph..
$1,250 |
View Details and Photo
|
|
LEYBOLD
WAU150 |
Single Stage Roots Pump.
Displacement: 104 cfm.
Flange: O. D. 6-5/8 in. I. D. 2-3/4 in.
4 bolt hole 3-5/8 in. on center square pattern.
Backing Pump Requirements: 27 cfm. 3450 rpm.
Motor: 1.5 HP. 208V, 6.7A, 60Hz, 3 Ph..
$1,250 |
View Details
|
|
LEYBOLD
WS250/D65BCS |
Pump and Blower Package.
Pump configured for Fomblin service.
Pumping Speed: 150 cfm.
220V, 3 Ph, 60 Hz.
Sold tested in good working order, but not rebuilt at this price..
$6,500 |
View Details and Photo
|
|
LEYBOLD CATHODE
- |
200mm cathode assembly..
$250 |
View Details and Photo
|
|
LEYBOLD HERAEUS
VDT-01 |
Vacuum System Controller..
$1,000 |
View Details
|